Heating, cooling, new installs, and repairs in Kendallville, Fort Wayne-area homes, and Noble County all come down to the same parts: contactor, capacitor, compressor, coil, heat exchanger, and the refrigerant on the label — R-22 on older equipment, R-410A on most systems we install now.

Click a part on the 3D unit. This is the same language we use on a Kendallville or Fort Wayne-area service call.

New install

How a furnace or AC install actually goes

  1. 01

    Size the house, not the old box

    We look at the house, the ducts, and how you live — then pick a matched Trane, RunTru, or Mitsubishi system. Square-footage charts are a starting point, not the job.

  2. 02

    Pull the old furnace or condenser

    Recover refrigerant the legal way. R-22 gets recovered, never vented. The old pad, vent, and electrical disconnect are inspected before anything new is set.

  3. 03

    Set the new equipment

    Level condenser, correct furnace clearances, new or reused lineset as the job allows, condensate, and a disconnect that matches the nameplate.

  4. 04

    Braze, vacuum, and charge

    Nitrogen while brazing. A deep vacuum on the lineset. A weighed-in R-410A charge. Gauges confirm; they do not replace the scale.

  5. 05

    Startup: parts that actually run

    We watch the contactor pull in, read the capacitor, check compressor and fan amps, set gas pressure and temperature rise, and prove airflow.

  6. 06

    Walkthrough

    Filter size, thermostat, what the outdoor unit should sound like, and who to call. One Kendallville number.

Ready for a replacement? Request a free estimate or see AC installation and furnace installation.

Parts glossary

Every part on the 3D units, in writing

Compressor

The pump in the outdoor condenser. It moves refrigerant between the indoor evaporator coil and the outdoor coil so heat can leave the house.

Contactor

compressor contactor

A 24-volt relay that sends 240-volt power to the compressor and outdoor fan when the thermostat calls for cool.

Dual run capacitor

start / run capacitor

Stores a charge that helps the compressor and condenser fan motor start and stay running. Most outdoor units use one dual-run can.

Condenser fan motor

Pulls air through the outdoor coil so the refrigerant can reject heat. If the fan dies, the compressor overheats.

Condenser coil

The outdoor coil. Refrigerant leaves heat here. Grass, cottonwood, and a bent fin pack make the system run hot and short-cycle.

Refrigerant: R-22 and R-410A

Freon, Puron

R-22 is the older chlorine refrigerant. New production is gone; remaining R-22 is for repair only and is expensive. R-410A is the common charge on systems installed over the last 15 years. The two oils and pressures do not mix. A new condenser is almost never a drop-in on an R-22 coil.

Lineset and service valves

The copper pair between the indoor coil and the outdoor unit: suction (large, insulated) and liquid (small). Service valves are where we gauge and charge.

Heat exchanger

The metal chamber that keeps combustion gases away from the air you breathe. A crack is a safety fail, not a parts swap you ignore.

Hot surface ignitor

Glows to light the burners. Fragile. A common no-heat part on January mornings in Noble County.

Flame sensor

A thin rod that proves the burners are lit. If it is dirty, the gas valve opens and then slams shut.

Inducer motor

Pulls combustion air through the heat exchanger and out the vent. The furnace will not open the gas valve if this motor does not prove draft.

Blower motor

Moves air across the heat exchanger and the evaporator coil. PSC motors and ECM / variable-speed motors are both common in this county.

Evaporator coil

A-coil, indoor coil

Sits on the furnace or in the air handler. Refrigerant boils here and absorbs heat from the house air. It must match the outdoor condenser.

TXV / expansion valve

thermostatic expansion valve

Meters liquid refrigerant into the evaporator. A piston is the simpler cousin. Wrong metering is a charge problem that never goes away.

Filter and return

The cheapest part, and the one that kills capacitors, blower motors, and coils when it is ignored.

Control board

The furnace brain: inducer, ignitor, gas valve, blower timings, and the 24-volt signal out to the AC contactor.

Questions

Refrigerant, repairs, installs

Ready when you are

Need a part diagnosed — or a new system?

A short note is enough. If the heat or AC is down, call — that is faster than a form.